Milk Coolers Cap: 300 ltr to 5000 ltr

Availability: In stock

QUICK OVERVIEW

Overview
HCHADHA Bulk Milk Coolers can be utilized for bringing down the temperature of milk from 35°C to 4°C within only 3 hours. These are triple jacketed, insulated tanks which are linked with an air condensing system. Once the milk reaches 4°C, it will rise to only 7°C even after 12 hours of being stored, hence increasing the shelf life of the milk considerably. HCHADHA Bulk Milk Coolers come with direct expansion plates covering almost 1/3rd of the internal surface area of the tanks. Hygiene being the primary focus, the internal edges are rounded in order to avoid deposition at the edges.

 

Types and capacities
Tank Type Capacities
Vertical Cylindrical Tank 300 litres, 500 litres
Horizontal Semi Cylindrical Tank 1000 litres, 2000 litres
Horizontal Cylindrical Tank 1000 litres, 2000 litres, 3000 litres, 5000 litres

 

Compare
Category:
DESCRIPTION TYPE MAKE OF COMPRESSOR MODEL NO. OF COMPRESSORS REQUIRED COOLING CAPACITY COMPRESSOR COOLING CAPACITY TONNAGE NO. OF FAN TYPE OF REFRIGERANT
BMC 300 LTRS. DIRECT EXPANSION EMERSON /COPELAND KCJ-511 ONE 1487 KCAL/HR 2250 KCAL/HR 0.75 TR 1 NO. R-22
BMC 500 LTRS. DIRECT EXPANSION EMERSON /COPELAND CR-22 ONE 2479 KCAL/HR 4788 KCAL/HR 1.58 TR 1 NO. R-22
BMC 1000 LTRS. DIRECT EXPANSION EMERSON /COPELAND CR-36 ONE 4959 KCAL/HR 7535 KCAL/HR 2.5 TR 1 NO. R-22
BMC 2000 LTRS. DIRECT EXPANSION EMERSON /COPELAND CR-36 X 2 TWO 9918 KCAL/HR 7535 X 2 KCAL/HR 2.5 TR X 2 2 NOS. R-22
BMC 3000 LTRS. DIRECT EXPANSION EMERSON /COPELAND CR-53 X 2 TWO 14876 KCAL/HR 11340 X 2 KCAL/HR 3.75 TR X 2 4 NOS. R-22
BMC 5000 LTRS. DIRECT EXPANSION EMERSON /COPELAND ZR81 X 2 TWO 24794 KCAL/HR 16120 X 2 KCAL/HR 5.33 TR X 2 4 NOS. R-22
DESCRIPTION RATED CAPACITY GROSS CAPACITY MAKE MATERIAL OF CONSTRUCTION FINISHING TYPE OF TANK THICKNESS OFINNER SHEET THICKNESS OF OUTER SHEET RPM & NO. OF AGITATOR CIP TYPE OF INSULATION THICKNESS OF INSULATION EFFICIENCY OF INSULATION
BMC 300 LTRS. 300 LTRS. 300 LTRS. NETCO AISI S.S.304 2 B CIRCULAR VERTICAL 1.5 MM 1.5 MM 21 RMP & ONE MANUAL P.U.F 50 MM AS PER ISO 5708
BMC 500 LTRS. 500 LTRS. 500 LTRS. NETCO AISI S.S.304 2 B CIRCULAR VERTICAL 1.5 MM 1.5 MM 21 RMP & ONE MANUAL P.U.F 50 MM AS PER ISO 5708
BMC 1000 LTRS. 1000 LTRS. 1000 LTRS. NETCO AISI S.S.304 2 B HORIZONTAL SEMI CYLINDRICAL 1.5 MM 1.5 MM 21 RMP & ONE MANUAL P.U.F 50 MM AS PER ISO 5708
BMC 2000 LTRS. 1000 LTRS. 1000 LTRS. NETCO AISI S.S.304 2 B HORIZONTAL SEMI CYLINDRICAL/ HORIZONTAL ELEPTICAL CLOSE 1.5 MM 1.5 MM 21 RMP & ONE MANUAL P.U.F 50 MM AS PER ISO 5708
BMC 3000 LTRS. 3000 LTRS. 3000 LTRS. NETCO AISI S.S.304 2 B HORIZONTAL ELEPTICAL CLOSE 1.5 MM 1.5 MM 21 RMP & ONE MANUAL P.U.F 50 MM AS PER ISO 5708
BMC 5000 LTRS. 5000 LTRS. 5000 LTRS. NETCO AISI S.S.304 2 B HORIZONTAL ELEPTICAL CLOSE 1.5 MM 1.5 MM 21 RMP & ONE MANUAL P.U.F 50 MM AS PER ISO 5708
DESCRIPTION AMBIENT TEMP. MAX COOLING TIME EVAPORATOR COOLING SURFACE AREA MINIMUM MILK REQUIRED MILK TEMP. RANGE POWER REQUIREMENT
BMC 300 LTRS. 38 DEG.C 3.0 HOURS 0.60 SQ.M 25 LTRS 35 DEG. TO 4 DEG. SINGLE PHASE
BMC 500 LTRS. 38 DEG.C 3.0 HOURS 0.60 SQ.M 25 LTRS 35 DEG. TO 4 DEG. SINGLE PHASE
BMC 1000 LTRS. 38 DEG.C 3.0 HOURS 1.22 SQ.M 30 LTRS 35 DEG. TO 4 DEG. SINGLE/THREE PHASE
BMC 2000 LTRS. 38 DEG.C 3.0 HOURS 2.88 SQ.M 300 LTRS 35 DEG. TO 4 DEG. SINGLE/THREE PHASE
BMC 3000 LTRS. 38 DEG.C 3.0 HOURS 2.28 X 2 SQ.M 400 LTRS 35 DEG. TO 4 DEG. SINGLE/THREE PHASE
BMC 5000 LTRS. 38 DEG.C 3.0 HOURS 3.36 X 2SQ.M 500 LTRS 35 DEG. TO 4 DEG. SINGLE/THREE PHASE
DESCRIPTION COMPRESSOR CONDENSOR FAN AGITATOR MOTOR MILK PUMP RECOMMENDED DG SET RECOMD. SERVO STABILIZER KW UNITS CONSUMED/HR WITH MILK PUMP KW UNITS CONSUMED/HR WITHOUT MILK PUMP PACKED DIMENSION (LXBXH)(Approx) OVERALL DIMENSION OF BMC(Approx)
BMC 300 LTRS. 1 X 4.70 = 4.70 AMP 1 X 0.42 = 0.42 AMP 1 X 0.35 = 0.35 AMP 1 X 2.00= 2.00 AMP 5 KVA 5 KVA 1.718 KWH 1.2581 KWH 56”X48”X69” 53”X 44”X 73”
BMC 500 LTRS. 1 X 8.0 = 8 AMP 1 X 0.85= 0.85 AMP 1 X 0.35 = 0.35 AMP 1 X 2.00= 2.00 AMP 5 KVA 5 KVA 2.5 KWH 2.116KWH 84”X49”X54” 79”X 44”X 73”
BMC 1000 LTRS. 1 X 12.4 = 12.4 AMP 1 X 0.85 AMP 1 X 0.35 = 0.35 AMP 1 X 2.00= 2.00 AMP 7.5 KVA 7.5 KVA 3.588 KWH 3.128 KWH 97”X61”X63” 92”X 53”X 86”
BMC 2000 LTRS. 2 X 12.4= 24.8 AMP 2 X0.85 AMP = 1.70 AMP 1 X 0.35 = 0.35 AMP 1 X 2.00= 2.00 AMP SINGLE PH.15KVA& 3 PH. 10 KVA SINGLE PH.15KVA& 3 PH. 10 KVA 6.6355 KWH 6.17 KWH 114”X58”X64” 112” X 56” X 74 “
BMC 3000 LTRS. 2 X 9 = 18 AMP 4 X 0.5 AMP = 4 AMP 1 X 0.55 AMP = 0.55 AMP 1 X 2 AMP = 1.20 AMP 25 KVA 25 KVA 13.65 KWH 12.96 KWH 108”X76”X101” 98” X 73” X 109 “
BMC 5000 LTRS. 2 X 13 = 26 AMP 4 X 0.5 AMP= 4 AMP 1 X 0.55 AMP = 0.55 AMP 1 X 2 AMP = 1.20 AMP 30 KVA 30 KVA 18.25 KWH 17.56 KWH 144”X78”X97” 133” X 75” X 109”

Salient Features

Salient Features

  • The construction material used in all thanks for all layers of the bulk milk cooler are made out of SS304 only.
  • All piping and connections are also made out of authentic SS304
  • Only branded condensing units are used of EMERSON or COPELAND make.
  • The condensing units are tuned for economic power consumption.
  • High quality agitator motor of “Serum” design used for long lasting performance of the agitator.
  • Only 1.5 mm SS sheets are used.
  • 3 mm MS flats used to provide further rigidity to the tanks.
  • Butterfly valves are used for easy connection with milk pumps for “no-hands” transfer of milk to and from the tank.
  • Option for heated CIP (Clean In Place) system is also available.